Seitenansicht 92
nlscan.com
Page 85
Symbols
Tools
Code Programming ON
Code Programming OFF
Standard 25
Check Digit
Standard 25 may include Check Digit (not compulsory) following its
barcode messages. If included, it may be the last digit. It verifies the barcode
message.
NO Check, Transmit All means to read without check and trans- »
mit all bytes including barcode message and Check Digit.
Check, Do Not Transmit Check Digit means to read and check. »
If verification is successful, transmits barcode message; if not, engine sends
an error beep.
Check, Transmit All means to read and check. If verification is »
successful, transmits all messages; if not, engine sends an error beep.
When Check, Do Not Transmit Check Digit is enabled and barcode message length
minus one is less than Min Message Length, it will lead to error beep.
E.g.Reading a 4-byte (include Check Digit) Standard 25 with the Min Message Length
being 4 bytes and Check, Do Not Transmit Check Digit enabled leads to error beep.
NO Check, Transmit All
Pro CMD99912203
Check, Do Not Transmit Check Digit
Pro CMD99912205
Check, Transmit All
Pro CMD99912204