Newland FM420 Handbuch Seite 135

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 156
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 134
nlscan.com
Page 126
Prex/SufxPrex/Sufx
Code Programming ON
Code Programming OFF
Tools
Program CODE as user sufx (The hex of CODE are 0x43, 0x4F, 0x44, and
0x45):
1. Read Code Programming ON
2. Read Program User Sufx
3. Read 4,3,4,F,4,4,4,5 in order
4. Read Save Programming
5. Read Code Programming OFF
6. Read Allow User Sufx to enable above programming. CODE will
appear to the right of a barcode.
User Sufx
Disable or Enable User Sufx
User sufx is appended to the right of barcode message. For example, if user sufx
is AB, and the barcode message is 123, The Host receives 123AB.
**Disable User Sufx
Pro CMD0306000
Enable User Sufx
Pro CMD0306010
Program User Sufx
Read Program User Sufx. Then program user sufx byte(s). To end the
sufx, read Save programming. The user sufx byte is programmed in its
hex values. See example below.
Note: The maximum length for user sufx is 10 bytes.
Program User Sufx
Pro CMD0301000