nlscan.com
Page 20
Getting Start
Code Programming ON
Code Programming OFF
Tools
“Send Sys Info”, the engine sends system information to the Host immediately.
“Power ON, Send Sys Info”, the engine sends system information to the Host right after Power
ON.
Send Sys Info【Pro CMD:0003000】
System Information
Title Remarks
Dev device type
Ver BIOS version
Date BIOS version establishing time
S/N device serial number
ESN user-defined device serial number
Interface 3 types of communication interfaces:
USB, append narration could be HID-KBW, DataPipe, Virtual RS232.1.
RS232, append narration could be baud rate, parity check byte, data bit and stop bit, in the 2.
order.
PS/2, no append narration3.
1D Indicate that reading 1D is
allowed. Symbologies are divided by comma. Appended information:
1. “+” affiliate features
2. Min Message Length -> Max Message Length
3. “No Check Digit” for do parity check,“Check Digit” for the contrary
4. “Fixed Length: 2~64 even value”. It is in this format: Fixed Length: 2 4 6 8 10 12...
2D Indicate that reading 1D is allowed. Symbologies are divided by comma. Appended information:
Min Message Le
ngth -> Max Message Length
Scan Mode 1. Manual Scan = “Hand-held Mode” in this book
2. Auto Scan = “Continuous Mode” in this book
3. Induced Scan = “Sensor Mode” in this book
The system information is provided in such format
Title: contents (append narration 1, narration 2)
Power ON, Send Sys Info
【Pro CMD:0007010】
** Power ON, Not Send Sys Info
【Pro CMD:0007000】