nlscan.com
Page 18
Mechanical Interface
Housing Design Considerations
Housing Structure
The housing for the Engine should be wide enough not to put any pressure on the Engine. There should be
sufficient space for the flexible cable and stress release of the cable should also be considered.
Scan Window
A scan window is needed to protect camera lens, aiming light, and illumination lights. This scan window
design should follow:
Hous » ing must not block or shade illumination LEDs, aiming light, and camera lens.
Use high trans » parent and scratch resistant material,such as both side hard coated material. Please refer to fol-
lowing specifications:
Item Specifications
Dimension
Size (mm) SIZE 1±1.0%
Thickness (mm) ±10%
Property
Total light transmittance (%) 90% (ASTM D 1008)
Haze (%) <1.0% (ASTM D 1008)
Stylus 4H (JIS K 5400)
Adhesion Not release
Appearance
Pinhole particle bubble
0.3~0.5 5EA
<0.3 5EA
Scratch 0.1mm (not crowded)
Under
0.05~3mm
3EA
Chemical IPA80%
Evaluation after 1 minute
dipPing
The gap and angle between housing window and illumination LED (highest point) must ensure that »
the illumination light should not be reflected into lens by window glass.
The window must be perpendicular to the surface of the front plate of the EM3000. »
Temperature
Electrical and other components generate heat. Especially under continuous operation, the temperature of the
Engine will be high. The methods below are for heat concerns:
A radiator on top of the engine is recommended
Do not surround or wrap the Engine by rubber or any material that obstruct the heat dissipation.
Seitenansicht 26