Newland EM3000 Spezifikationen Seite 59

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 159
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 58
nlscan.com
Page 50
RS232 InterfaceRS232 Interface
Code Programming ON
Code Programming OFF
Tools
Parity Check
Parity check options should be the same on the engine and the Host.
Select Odd parity: If data has an odd number of 1 bits, the parity bit »
value is set to 0.
Select Even parity:If data has an even number of 1 bits, the parity bit »
value is set to 0.
Select No Parity Check and parity bit will not be sent. »
**No Parity Check
Pro CMD0101000
Even Check
Pro CMD0101010
Odd Check
Pro CMD0101020
Serial Port
Hardware Auto Flow Controlonly for HR200
When enabledHR200 will decide if the data should be sent in accordance with CTS signal level. When it
is low level CTS signal, it means the serial ports cache memory of receiving end (such as PC) is full and
HR200 will not send data through RS232 until CTS signal is set to high level by receiving end.
When HR200 is not ready for receiving, it will set RTS signal to low level. When sending end (such as PC)
detects it, it could not send data to HR200 any more, otherwise the data will be lost.
When disabled, datas sending and receiving through serial port will not be effected by RTS/CTS signal.
**Disable Hardware Auto Flow Control
Pro CMD0104000
Enable Hardware Auto Flow Control
Pro CMD0104010
Before enabling this function, please be sure that RTS/CTS signal line is contained in RS232
cable. If not, a RS232 communication error will occur.
Seitenansicht 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 158 159

Kommentare zu diesen Handbüchern

Keine Kommentare