Newland EM3000 Spezifikationen Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 159
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
nlscan.com
Page 21
Electrical Interface
Input signals
Trigger Input
When the Trigger line is pull low for20 ms, the Engine starts a read. The Engine keeps reading until
a successful reading or the line is high. After a successful reading, the line must go high in order to
make another reading.
Sample Input schematics
Here is a schematic from the evaluation board, EVK3000&1300. Those two signals can connect to
external devices output port.
Output Signals
Here are the descriptions of the output signals, beeper and LED. They can be used to detect the status
of the scanning and the state of the Engine.
Reset Input
The Engine restarts itself after the Reset line is pull low for 100μs and back to high. The LED
Pin will go low. The LED Pin will stay low until the Reset Pin is released and power is applied to
EM3000. After the initialization, if send-beep option is enabled, the Engine will send power on
beeper signal.
Beeper Output
Table below is the definitions of the beeper outputs:
Beep Pattern Definitions
Low-higher-higher-higher Power ON completed
1 beep Successful reading of an ordinary barcode
2 beeps Successful reading of an programming barcode
3 short low-2 high Reading failure
1 long low Unknown Character, Virtual Keypad (USB connection)
1
2
3
4
5
6
7
8
9
10
11
12
BUZ
TXD
TR IG
/RESET
LED
VCC_3.3V
RXD
R1
10R
1
2
B1
BUTTON
1
2
B2
BUTTON
1
2
12 Pins Flex Cable